Kontron COMe-bCD2 User Manual

Browse online or download User Manual for Hardware Kontron COMe-bCD2. Kontron COMe-bCD2 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - COMe-bCD2

Kontron User's Guide COMe-bCD2 Document Revision 120

Page 2

2 Introduction Kontron User's Guide ETXexpress® CD 10 The COMe-bCD2 uses the Pin-out Type 2 architecture, which includes PCI and

Page 3 - Table of Contents

2 Introduction Kontron User's Guide ETXexpress® CD 11 2.4 Understanding COM Express® functionality All Kontron COM Express® basic and compac

Page 4

2 Introduction Kontron User's Guide ETXexpress® CD 12 2.6 COM Express® Benefits COM Express® basic modules are very compact (125 x

Page 5

3 Specifications Kontron User's Guide ETXexpress® CD 13 3 Specifications 3.1 Functional Specifications Processor Intel® Celeron® M, Core D

Page 6 - 1 User Information

3 Specifications Kontron User's Guide ETXexpress® CD 14 PCI Express: Intel® ICH7M-DH 5 PCI Express x1 lanes Optionally 1 x4 lane and 1 x1

Page 7 - 1.6 Technical Support

3 Specifications Kontron User's Guide ETXexpress® CD 15 AC ’97 (Audio): Intel® 945GM/GME; Up to 20 bit sample resolution Multiple sample ra

Page 8 - 2 Introduction

3 Specifications Kontron User's Guide ETXexpress® CD 16 3.1.1 Block diagram DDR2-SDRAMLCD (JILI)CRTIDEUSB0-7Connector ABAC’97SoundRTCMISCPow

Page 9 - 2.2.2 Dual Channel Version

3 Specifications Kontron User's Guide ETXexpress® CD 17 3.2 Mechanical Specifications Dimensions 95.0 mm x 125.0 mm Height approx. 12 mm (

Page 10

3 Specifications Kontron User's Guide ETXexpress® CD 18 3.4 Environmental Specifications 3.4.1 Temperature Operating: (with Kontron Embedde

Page 11

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 19 4 Connector Pinouts 4.1 Connector location There are 2 connectors on the basic s

Page 12 - 2.6 COM Express® Benefits

This page intentionally left blank

Page 13 - 3 Specifications

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 20 4.2 Pinout tables Type Signal Description I Differential Pair Input IO-2,5 Bi-dir

Page 14

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 21 4.2.1 Connector X1A Connector X1A (Signal Levels A1-A55) Pin A1-A55

Page 15

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 22 Connector X1A (Signal Levels A56-A110) Pin A56-A110 [ Powe

Page 16 - ETXexpress-CD

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 23 Connector X1B (Signal Levels B1-B55) Pin B1-B55 [ LAN | Power |

Page 17 - 3.3.1 Power Consumption

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 24 Connector X1A (Signal Levels B56-B110) Pin B56-B110 [ Power

Page 18 - 3.5 MTBF

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 25 4.2.2 Connector X1B Connector X1B (Signal Levels C1-C55) Pin A1-A55

Page 19 - 4 Connector Pinouts

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 26 Connector X1B (Signal Levels C56-C110) Pin C56-C110 [ Powe

Page 20 - 4.2 Pinout tables

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 27 Connector X1B (Signal Levels D1-D55) Pin D1-D55 [ LAN | Power |

Page 21 - 4.2.1 Connector X1A

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 28 Connector X1B (Signal Levels D56-D110) Pin D56-D110 [ LAN | Power |

Page 22

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 29 4.3 Signal description 4.3.1 PCIexpress x1 lanes The PCI express x1 lanes i

Page 23

Table of Contents Kontron User's Guide ETXexpress® CD iii Table of Contents 1 User Information ...

Page 24

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 30 250MHz core render clock and 200 MHz core display clock at 1.05V core voltage Su

Page 25 - 4.2.2 Connector X1B

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 31 Configuration The Ethernet interface is a PCIexpress device. The BIOS set

Page 26

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 32 For additional information, refer to the COM Express® Design Guide, I2C

Page 27

4 Connector Pinouts Kontron User's Guide ETXexpress® CD 33 Serial Digital Video Out Port (DVOB & DVOC) support Two 12-bit channels The

Page 28

5 Special Features Kontron User's Guide ETXexpress® CD 34 5 Special Features 5.1 Watchdog Timer This feature is implemented in the Xi

Page 29 - 4.3 Signal description

6 Important Information Kontron User's Guide ETXexpress® CD 35 6 Important Information Kontron Embedded Modules currently offers differ

Page 30 - 4.3.9 Ethernet

7 Design Considerations Kontron User's Guide ETXexpress® CD 36 7 Design Considerations 7.1 Thermal Management A heat-spreader plate assemb

Page 31 - 4.3.11 Power Management

7 Design Considerations Kontron User's Guide ETXexpress® CD 37 7.2 COMe-bCD2 onboard Fan connector This section describes how to connect a f

Page 32 - 4.3.16 SDVO Output

7 Design Considerations Kontron User's Guide ETXexpress® CD 38 Part number (Molex) J4: 53261-0390 Mates with: 51021-0300 Crimp te

Page 33

7 Design Considerations Kontron User's Guide ETXexpress® CD 39 7.2.2 BIOS settings for fan control 7.2.3 Electrical Characteristics VC

Page 34 - 5 Special Features

Table of Contents Kontron User's Guide ETXexpress® CD iv 4.3.6 VGA Output ...

Page 35 - 6 Important Information

7 Design Considerations Kontron User's Guide ETXexpress® CD 40 Note: The VCC_in_FANCON output is not short circuit proof. If necessary the

Page 36 - 7 Design Considerations

8 Important Technology Information Kontron User's Guide ETXexpress® CD 41 8 Important Technology Information The following technological inf

Page 37

8 Important Technology Information Kontron User's Guide ETXexpress® CD 42 Automatic mode does not require any additional hardware, so

Page 38

8 Important Technology Information Kontron User's Guide ETXexpress® CD 43 8.4 Thermal Management ACPI allows the OS to play a role in the th

Page 39

9 System Ressources Kontron User's Guide ETXexpress® CD 44 9 System Ressources 9.1 Interrupt Request (IRQ) Lines In 8259 PIC mode: IRQ # Us

Page 40

9 System Ressources Kontron User's Guide ETXexpress® CD 45 In APIC mode: IRQ # Used For Available Available for PCI Comment 0 Timer0 No No 1

Page 41 - 8.1 I/O APIC mode

9 System Ressources Kontron User's Guide ETXexpress® CD 46 9.3 Memory Area Upper Memory Used for Available Comment C0000h – CFFFFh VGA BIOS

Page 42 - 8.2.1 Summary

9 System Ressources Kontron User's Guide ETXexpress® CD 47 9.7 System Managment (SM) Bus Following SM bus addresses are reserved. SM Bus Add

Page 43 - 8.4 Thermal Management

10 BIOS Operation Kontron User's Guide ETXexpress® CD 48 10 BIOS Operation The module is equipped with a Phoenix BIOS, which is located in a

Page 44 - 9 System Ressources

10 BIOS Operation Kontron User's Guide ETXexpress® CD 49 Menu Bar The menu bar at the top of the window lists different menus. Use the left/

Page 45

Table of Contents Kontron User's Guide ETXexpress® CD v 9.6 Inter IC (I2C) Bus ...

Page 46

11 BIOS Setup Kontron User's Guide ETXexpress® CD 50 11 BIOS Setup 11.1 Info Screen 11.2 Main Menu Feature Option Description System Ti

Page 47 - 9.8 JILI I

11 BIOS Setup Kontron User's Guide ETXexpress® CD 51 11.2.1 IDE Channels Submenu Feature Option Description Type User Auto CD-ROM ATAPI Rem

Page 48 - 10 BIOS Operation

11 BIOS Setup Kontron User's Guide ETXexpress® CD 52 11.3 Advanced Feature Option Description PNP OS installed Other Win95 Win98 WinME Win2

Page 49 - Function

11 BIOS Setup Kontron User's Guide ETXexpress® CD 53 11.3.1 Keyboard Features Submenu Feature Option Description NumLock Auto On Off Select

Page 50 - 11 BIOS Setup

11 BIOS Setup Kontron User's Guide ETXexpress® CD 54 11.3.2 Cache Memory Submenu Feature Option Description Memory Cache Disabled Enabled S

Page 51 - 11.2.1 IDE Channels Submenu

11 BIOS Setup Kontron User's Guide ETXexpress® CD 55 Feature Option Description Write Back Cache D000-D3FF Disabled Write Through Write Prot

Page 52 - 11.3 Advanced

11 BIOS Setup Kontron User's Guide ETXexpress® CD 56 11.3.3 Hardware Monitor Submenu Feature Option Description Edges Per Fan Revolution 0

Page 53

11 BIOS Setup Kontron User's Guide ETXexpress® CD 57 11.3.4 Watchdog Settings Submenu Feature Option Description Mode Disabled Reset NMI Wa

Page 54 - 11.3.2 Cache Memory Submenu

11 BIOS Setup Kontron User's Guide ETXexpress® CD 58 11.3.5 Miscellaneous Submenu Feature Option Description Enabled memory gap Disabled Ex

Page 55

11 BIOS Setup Kontron User's Guide ETXexpress® CD 59 11.3.6 Console Redirection Submenu Feature Option Description Console Disabled UCR, CO

Page 56

1 User Information Kontron User's Guide ETXexpress® CD 6 1 User Information 1.1 About This Manual This document provides information about

Page 57

11 BIOS Setup Kontron User's Guide ETXexpress® CD 60 11.4 Devices Feature Option Description Clock generator Default Program Controls progr

Page 58

11 BIOS Setup Kontron User's Guide ETXexpress® CD 61 11.4.1 CPU Control CPU control detects which processor core is used and displays an add

Page 59

11 BIOS Setup Kontron User's Guide ETXexpress® CD 62 CPU Thermal Control Feature Option Description Thermal Control Circuit Disabled TM1 TM2

Page 60 - 11.4 Devices

11 BIOS Setup Kontron User's Guide ETXexpress® CD 63 Feature Option Description 79C 87 C 95 C 103 C 111 C 119 C Passive TC1 Value 0 1 2 3 4 5

Page 61 - 11.4.1 CPU Control

11 BIOS Setup Kontron User's Guide ETXexpress® CD 64 Feature Option Description 47 C 55 C 63 C 71 C 79C 87 C 85 C 103 C 111 C 119 C 127 C

Page 62

11 BIOS Setup Kontron User's Guide ETXexpress® CD 65 11.5 Chipset Control Feature Option Description PCI Express Graphics Port Disabled Au

Page 63

11 BIOS Setup Kontron User's Guide ETXexpress® CD 66 Feature Option Description If disabled, bus master traffic is a break event and it will

Page 64

11 BIOS Setup Kontron User's Guide ETXexpress® CD 67 11.6 Integrated Video Feature Option Description Default Video Priority IGD or PEG PEG

Page 65 - 11.5 Chipset Control

11 BIOS Setup Kontron User's Guide ETXexpress® CD 68 11.6.1 Display Control Feature Option Description Display Mode CRT only TV only LVDS o

Page 66

11 BIOS Setup Kontron User's Guide ETXexpress® CD 69 Feature Option Description HD Audio device Disabled Auto Control Detection of the HD Au

Page 67 - 11.6 Integrated Video

1 User Information Kontron User's Guide ETXexpress® CD 7 The warranty does not apply to defects resulting from improper or inadequate mainten

Page 68 - 11.6.1 Display Control

11 BIOS Setup Kontron User's Guide ETXexpress® CD 70 11.7.1 PCI Express Ports Feature Option Description PCI Express – Root Port 1 Disabled

Page 69

11 BIOS Setup Kontron User's Guide ETXexpress® CD 71 11.7.2 PCI/PNP ISA IRQ Ressource Exclusion Feature Option Description PCI IRQ line 1 -

Page 70 - 11.7.1 PCI Express Ports

11 BIOS Setup Kontron User's Guide ETXexpress® CD 72 11.7.3 USB Ports Feature Option Description USB Controller Disabled Enabled Controls t

Page 71

11 BIOS Setup Kontron User's Guide ETXexpress® CD 73 11.8 LAN Options Feature Option Description LAN MAC address LAN Controller #1 Disabl

Page 72 - 11.7.3 USB Ports

11 BIOS Setup Kontron User's Guide ETXexpress® CD 74 11.9 SIO Options Feature Option Description Serial port A Disabled Enabled Auto Config

Page 73 - 11.8 LAN Options

11 BIOS Setup Kontron User's Guide ETXexpress® CD 75 Feature Option Description 3BC Interrupt IRQ 5 IRQ 7 Set the interrupt for the parallel

Page 74 - 11.9 SIO Options

11 BIOS Setup Kontron User's Guide ETXexpress® CD 76 11.10 Security Feature Option Description TPM Support Disabled Enabled Enable Trusted

Page 75

11 BIOS Setup Kontron User's Guide ETXexpress® CD 77 11.11 Power Feature Option Description After Power Failure Stay Off Last State Power O

Page 76 - 11.10 Security

11 BIOS Setup Kontron User's Guide ETXexpress® CD 78 11.11.1 ACPI Parameter Control Feature Option Description Enable ACPI No Yes En/Disabl

Page 77 - 11.11 Power

11 BIOS Setup Kontron User's Guide ETXexpress® CD 79 11.12 Boot Feature Option Descpription Boot priority order 1:USB Key 2:USB CDROM 3:IDE

Page 78

2 Introduction Kontron User's Guide ETXexpress® CD 8 2 Introduction 2.1 COMe-bCD2 Based on the COM Express standard, Kontron‟s COMe-bCD2, p

Page 79 - 11.12 Boot

11 BIOS Setup Kontron User's Guide ETXexpress® CD 80 11.13 Exit Feature Description Exit Saving Changes Exit System Setup and save your c

Page 80 - 11.13 Exit

2 Introduction Kontron User's Guide ETXexpress® CD 9 2.2 COMe-bCD2 Release Versions The COMe-bCD2 module is available in two differen

Comments to this Manuals