Kontron KTQM67-mITX User Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 148
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
KTQM67 Users Guide
KTD-N0819-K Page 58
6.12 Feature Connector (FEATURE) (J30)
Note
Pull
U/D
Ioh/Iol Type Signal PIN Signal Type Ioh/Iol
Pull
U/D
Note
2
2M/
-
I
CASE_OPEN#
1
2
SMBC
/4mA
10K/
1
-
25/25mA
O
S5#
3
4
SMBD
/4mA
10K/
1
-
25/25mA
O
PWR_OK
5
6
EXT_BAT
PWR
-
-
-
O
FAN3OUT
7
8
FAN3IN
I
-
-
-
-
PWR
SB3V3
9
10
SB5V
PWR
-
-
-
IOT
GPIO0
11
12
GPIO1
IOT
-
-
IOT
GPIO2
13
14
GPIO3
IOT
-
-
IOT
GPIO4
15
16
GPIO5
IOT
-
-
IOT
GPIO6
17
18
GPIO7
IOT
-
-
-
PWR
GND
19
20
GND
PWR
-
-
-
I
GPIO8
21
22
GPIO9
I
-
-
I
GPIO10
23
24
GPIO11
I
-
-
I
GPIO12
25
26
GPIO13
IOT
-
-
IOT
GPIO14
27
28
GPIO15
IOT
-
-
IOT
GPIO16
29
30
GPIO17
IOT
-
-
-
PWR
GND
31
32
GND
PWR
-
-
-
8/8mA
O
EGCLK
33
34
EGCS#
O
8/8mA
-
-
8/8mA
EGAD
35
36
TMA0
O
-
PWR
+12V
37
38
GND
PWR
-
-
-
O
FAN4OUT
39
40
FAN4IN
I
-
-
-
-
PWR
GND
41
42
GND
PWR
-
-
-
-
PWR
GND
43
44
S3#
O
25/25mA
-
Notes: 1. Pull-up to +3V3Dual (+3V3 or SB3V3).
2. Pull-up to on-board Battery.
3. Pull-up to +3V3.
Available cable kit: